Features

  • Compatible with Gas, Liquid, or Vapor.
  • Issues automated warning in the event of bearing or lubrication failure.
  • Identifies steam trap issues and valve leakage
  • 2-mile communication range between sensor and gateway

Sensor Environmental Regulatory Qualifications

  • Temperature Operation Range  -30°C to +80°C
  • Operating Range 0.500 mA DC to 16.280 mA DC @ 0.158 mA/dB of Change in Detected Ultrasonic Signal
  • Accuracy ±0.5%FS (pressure)  ±1.5℃ (Temperature)
  • Sampling Frequency 1.5ms
  • 10/32 UNF Mounting Hole
  • CE/UKCA Certified
  • Water and Dust Proof Enclosure (IP67) NEMA 6p

Sensor Data

Power Supply Voltage- 23 to 26 V, DC power source @ 30

Specifications

  • Wireless Frequency 900MHz
  • 128bit AES encryption  
  • Sensor: 6.5"L x 4.25"W x 3"H
  • Sensor Weighs 1.6 lbs
  • Gateway: 13.75"L (with antennae) x 5.5"W x 2.5"H
  • Gateway Weighs 1.15 lbs

Applications

  • Bearing Condition Monitoring and Lubrication
  • Valve and Steam Trap Monitoring

Installation

  • Prepare the mounting surface.
  • Mix the 2-part epoxy using the instruction included with the kit and apply.
  • Press on the plastic piece of the mounting kit until it clicks.
  • Wait 10 – 15 minutes.
  • Remove the plastic mounting kit from the stud.
  • Thread the sensor onto the stud.

See below for an example:  

 

 

Motor Fin Mount

  • Measure the depth and width of cooling fan to select the proper Motor Fin Mount.
  • Verify the Motor Fin Mount is long enough to make direct contact with the motor case between the fins.
  • Add LOCTITE AA HH3300 adhesive is then used to hold the mount in place.

The thickness of the mount will minimize the amount of adhesive needed.

When mounted correctly the sensor should sit firmly in place and not be able to wobble or easily move.

Additional Specifications

  • Power Supply Voltage- 23 VDC to 26 VDC
  • Power Supply Current Draw- 30mA DC Max
  • Current Output Type- Milliamp DC, Demodulated/Heterodyned
  • Current Output Compliance Voltage- 3.3 VDC
  • Current Output Response- Linear, Proportional to 0 dB to 100 dB of Change in Detected Ultrasonic Signal
  • Current Output Range- 0.500 mA DC to 16.280 mA DC @ 0.158 mA/dB of Change in Detected Ultrasonic Signal
  • dB Output Transfer Function- dB Output = + 6.321 x (Current Output Reading), mA DC - 2.917 dB
  • Current Output Accuracy- Less Than ±1 dB of Reading
  • Ambient Operating Temperature Range- Standard Range = -20 °C to +60 °C , Extended Range = -30 °C to +80 °C (Requires High Temperature Cable)
  • Current Output (Temperature)- +2 dB @ - 20 °C, -2 dB @ +60 °C +3dB @ -30 °C, -4 dB @ +80 °C
  • Sensitivity Adjustment- Automatic, Thru the 0 dB to 100 dB Output Range
  • Connection Cable- 3 Wire with Shield Removable (Different Lengths Available)
  • Cable Lengths- Different Lengths Available
  • Cable/Housing Connector- Harsh Environment, Meets or Exceeds IP67 and NEMA 6P
  • Cable/Housing- Shielding RF
  • Housing- Stainless Steel, Water Resistant and Dust Proof, Meets or Exceeds IP67 and NEMA 6P
  • Transducer- Piezoelectric
  • Method of Attachment- 10/32 Mounting Hole
  • Thermal Isolation Kit available